Page 11
2.4 Frequency Selection (216-217 MHz)
The PR-216 personal receiver can operate on one of 57 available channels
between 216 MHz and 217 MHz. COMTEK’s channel designations indicate
both standard narrow-band channels and high-fidelity, narrow-band
companded channels. Channels 1-40 are standard narrow-band channels
(5KHz deviation) offering compatibility with other manufacturers’
receivers such as the Phonak MicroEar. Channels 41-60 are high-fidelity,
narrow-band companded channels (10 KHz deviation) for use with
COMTEK transmitters. COMTEK transmitters automatically transmit the
proper modulation when set to channels 1-40 for standard narrow-band or
41-60 for narrow-band, high-fidelity companded channels.
After you have determined the channel on which you are going to operate,
position the two rotary switches to indicate the channel. The left rotary
switch is for tens and the right rotary switch is for ones. To select channel 41
(216.0250 MHz), position the left rotary switch to point to 4 (X10), and
position the right rotary switch to point to 1 (X1). Refer to frequency charts on
pages 14 and 15 for selectable frequencies.