Section 6 Trouble Shooting
Batteries and Battery Charging
If...
Test indicator lamp doesn’t illuminate when units are turned on...
Then...
• If rechargeable batteries are used, ensure that they have been allowed to
charge at least twelve hours to a full charge. Verify that the charging indicator
lamps are illuminated when the charging plugs are plugged into the units.
The units’ power switches must be in the “off ” position for charging.
• If the test indicator lamp still does not illuminate after a full charge, verify
that the system is operational by using a new alkaline battery. If the system
is operational with alkaline batteries, the rechargeable batteries or charger
may need to be replaced.
• The AT-216 system must be returned to COMTEK for service if the test
indicator lamps do not illuminate when new alkaline batteries are used.
Transmitter Audio Problem
If...
There is no visual indication on the “Voice” modulation level indicator
when speaking into the microphone of the M-216 transmitter...
Then...
• Turn up the microphone gain setting clockwise until the voice
modulation indicator illuminates with speech level.
• Make sure the optional muting switch is in the “Mic on” position.
• Check the SM-183 microphone for a broken or frayed microphone cord that
may cause intermittent operation.
• Test the modulation indicator with the auxiliary audio input using a line
level signal and the CB-36ST auxiliary audio input cable to verify normal
operation. If the auxiliary audio input activates the voice modulation
indicator normally, the SM-183 microphone may need to be repaired or
replaced.
• The AT-216 system must be returned to COMTEK for service if the auxiliary
input test does not activate the voice modulation indicator.